88T Fib-R-Thane Trowelable, Part A, Hardener SDS
Safety Data Sheet for Sauereisen, Inc. 88T Fib-R-Thane Trowelable, Part A, Hardener, revised 2016-06-28.


Hazards
- H332 Harmful if inhaled.
- H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.
- H335 May cause respiratory irritation.
- H315 Causes skin irritation.
- H317 May cause an allergic skin reaction.
- H320 Causes eye irritation.
- H372 Causes damage to respiratory tract through prolonged or repeated exposure if inhaled
Protective equipment
- Liquid chemical goggles. Vapor resistant goggles should be worn if contact lenses are in use. In a splash hazard environment, chemical goggles should be used in combination with a full face shield.
- Suitable protective gloves (neoprene, butyl rubber, or viton).
- Clothing should be clean, long-sleeved workclothes. Synthetic apron. Boots.
- Respiratory protection must be worn whenever concentrations of MDI exceed the TLV or in poorly ventilated areas. A supplied air respirator or a positive pressure self-contained breathing apparatus is
First aid
- Eyes: Check for and remove all contact lenses. Flush eyes immediately with water or physiological saline for at least 15 minutes while lifting upper and lower lids. Do not use eye ointment. Seek medical attention.
- Skin: Wash promptly with soap and water. If soaked through clothing, promptly remove clothing and wash skin. Launder clothing before reuse. Discard saturated shoes and leather clothing. For severe exposures, get under safety shower after removing clothing. Do not apply greases or ointments. Seek medical attention for incidents of significant exposure or if effects apparent.
- Swallowed: If swallowed, do not induce vomiting. Give large quantities of water. Seek medical attention immediately. Never give anything by mouth to an unconscious person.
- Breathing it in: If difficulty breathing, move to fresh air once. For acute overexposure, give oxygen if breathing is difficult. Apply artificial respiration if breathing has stopped. Seek medical attention. Asthmatic symptoms may develop and may be immediate or delayed up to several hours. Consult a physician should this occur.
Fire
Use water, carbon dioxide, dry chemical, or foam. Full emergency equipment including self contained breathing apparatus should be worn. At temperatures above 400F (204 C) polymeric MDI can polymerize and decompose, causing pressure build up in closed containers; use cold water to cool fire-exposed containers.
Spills
Evacuate and ventilate spill area. Dike spill to prevent entry into water system. Absorb isocyanates with sawdust or other absorbent, shovel into suitable unsealed containers, and treat with neutralizing solution. Wear full protective equipment, including respiratory equipment, during clean-up.
Summary taken from the SDS and checked by IDSDS. The full SDS is the official document.
En español
Pictogramas: Irritante / nocivo, Peligro para la salud
Peligros:
- Nocivo en caso de inhalación
- Puede provocar síntomas de alergia o asma o dificultades respiratorias en caso de inhalación
- Puede irritar las vías respiratorias
- Provoca irritación cutánea
- Puede provocar una reacción alérgica en la piel
- Provoca irritación ocular
- Provoca daños en los órganos tras exposiciones prolongadas o repetidas
Indicaciones de peligro en la redacción oficial del SGA en español. El equipo de protección y los primeros auxilios están arriba, como los dice la hoja. La hoja completa del fabricante es el documento oficial.