ADS-LT SDS
Safety Data Sheet for GPM ADS-LT, revised 2016-06-30.


Hazards
- H350 May cause cancer. Classified as carcinogenic Category 1 on the basis of epidemiological and/or animal data. Mixtures are classified as carcinogenic when at least 1 ingredient has been classified as carcinogenic and is present at 0.1% or above. Routes of exposure are dependant on ingredient form.
- H312 Harmful in contact with skin.
Protective equipment
- In order to avoid inhalation of spray-mist and sanding dust, all spraying and sanding must be done wearing adequate respirator.
- Sensitive individuals should wear gloves to prevent repeated contact.
- Safety glasses with side-shields
First aid
- Eyes: Flush eyes with water for at least 15 minutes. Get medical help if irritation persists.
- Skin: Wash with soap and water. Remove contaminated clothing and clean before reuse.
- Swallowed: Do not induce vomiting due to possible aspiration into the lungs. Have the victim drink 8 to 10 ounces (240 - 300 ml) of water to dilute the material in the stomach. If vomiting occurs naturally, have the victim lean forward. Consult a physician immediately.
- Breathing it in: Remove person to fresh air. If signs/symptoms continue, get medical attention.
Fire
Use a self-contained breathing apparatus with full facepiece operated in pressure-demand or other positive pressure mode. Use water spray to cool fire exposed containers. Container may rupture on heating. Extinguishing media: None Known.
Spills
Isolate hazard area and keep unnecessary people away. Do not allow the liquid to enter sewers, the ground or any body of water. For large spills, use a dike and pump into appropriate containers. For small spills, dilute with water and recover or use non-combustible absorbent material and shovel into waste containers.
Summary taken from the SDS and checked by IDSDS. The full SDS is the official document.
En español
Pictogramas: Irritante / nocivo, Peligro para la salud
Peligros:
- Puede provocar cáncer
- Nocivo en contacto con la piel
Indicaciones de peligro en la redacción oficial del SGA en español. El equipo de protección y los primeros auxilios están arriba, como los dice la hoja. La hoja completa del fabricante es el documento oficial.
Try IDSDS free